Total Turnkey Solutions
HomeProductLatest News and EventsTechnical SupportContact Us

Technical & Applications Notes and more

Easy Find Index

da_ban2.jpg (1632 bytes)

Low Cost Data Acquisition Starter Kits

  DI-194RS Data Acquisition Starter Kit DI-148U Data Acquisition Starter Kit DI-148U-SP Data Acquisition Starter Kit DI-158U Data Acquisition Starter Kit DI-158UP Data Acquisition Starter Kit

Features

DI-194RS DI-148U DI-148U-SP DI-158U DI-158UP
Channels 4 single-ended 8 single-ended 2 (string pot) 4 differential 4 differential
Resolution 10-bit 10-bit 10-bit 12-bit 12-bit
Full Scale Range ±10 VFS ±10 VFS ±10 VFS ±10 VFS ±64 VFS
Maximum Sample Rate 240 Hz 14,400 Hz 14,400 Hz 14,400 Hz 14,400 Hz
Interface Serial Port USB USB USB USB
Supported OS  Windows 2000 and XP   Windows 2000 and XP   Windows 2000 and XP   Windows 2000 and XP   Windows 2000 and XP 

 
Low-Cost Data Loggers

  EL-USB-1 Data Logger EL-USB-1-LCD Data Logger EL-USB-1-RCG Data Logger EL-USB-1-PRO Data Logger EL-USB-2 Data Logger EL-USB-2 Data Logger EL-USB-2-LCD Data Logger EL-USB-2-LCD+ Data Logger EL-USB-3 Data Logger EL-USB-4 Data Logger EL-USB-5 Data Logger EL-USB-TC Data Logger EL-USB-TC-LCD EL-USB-CO Data Logger EL-USB-RT
Features EL-USB-1 EL-USB-1-LCD EL-USB-1-RCG EL-USB-1-Pro EL-USB-2 EL-USB-2+ EL-USB-2-LCD EL-USB-2-LCD+ EL-USB-3 EL-USB-4 EL-USB-5 EL-USB-TC EL-USB-TC LCD EL-USB-CO EL-USB-RT
Function Temperature Temperature Temperature High 
Temperature
Humidity, Temperature, Dew Point Humidity, Temperature, Dew Point Humidity, Temperature, Dew Point Humidity, Temperature, Dew Point Voltage Process Current Event, State, Counter Thermocouple Thermocouple Carbon Monoxide Humidity, Temperature,
Dew Point
Range -35 to +80°C (-31 to +176°F) -35 to +80°C (-31 to +176°F) -35 to +60°C (-4 to +140°F) -40 to +125°C (-40 to +257°F) 0 to 100% RH
-35 to +80°C (-31 to +176°F)
0 to 100% RH
-35 to +80°C
(-31 to +176°F)
0 to 100% RH
-35 to +80°C (-31 to +176°F)
0 to 100% RH
-35 to +80°C (-31 to +176°F)
0 to 30 VDC 4 to 20 mA 3-28 VDC -130 to +900°C (J-type)
-200 to +1300°C (K-type)
-200 to +350°C (T-type)
-100 to +900°C (J-type)
-200 to +1300°C (K-type)
-200 to +400°C (T-type)
0 to 1000 ppm 0 to 100% RH
-20 to +70°C
(-4 to +158°F)
Sample Interval 10s, 1m, 5m, 30m, 1h, 6h, 12h 10s, 1m, 5m, 30m, 1h, 6h, 12h 1s, 10s, 1m, 5m, 30m, 1h, 6h, 12h 1s, 10s, 1m, 5m, 30m, 1h, 6h, 12h 10s, 1m, 5m, 30m, 1h, 6h, 12h 10s, 1m, 5m, 30m, 1h, 6h, 12h 10s, 1m, 5m, 30m, 1h, 6h, 12h 10s, 1m, 5m, 30m, 1h, 6h, 12h 1s, 10s, 1m, 5m, 30m, 1h, 6h, 12h 1s, 10s, 1m, 5m, 30m, 1h, 6h, 12h 1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr 1s, 10s, 1m, 5m, 30m, 1h, 6h, 12h 1s, 10s, 1m, 5m, 30m, 1h, 6h, 12h 10s, 30s, 1m, 5m 1s
Internal Resolution 0.5°C (1°F) 0.1°C (0.2°F) 0.1°C (0.2°F) 0.1°C (0.2°F) 0.5%RH
0.5°C (1°F)
0.5%RH
0.5°C (1°F)
0.5%RH
0.5°C (1°F)
0.5%RH
0.5°C (1°F)
50mV 0.05mA 0.05 0.5°C (1°F) 0.5°C (1°F) 0.5 ppm CO N/A
PC Interface USB USB USB USB USB USB USB USB USB USB USB USB USB USB USB
Memory Capacity 16,382 samples 16,382 samples 16,382 samples 16,510 samples 16,382 samples 16,382 samples 16,379 samples 16,379 samples 32,510 samples 32,000 samples 32,000 samples 32,000 samples 32,000 samples 32,510 samples N/A
Stand-alone Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No
Alarms N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Cell phone text message,
 Email, Audible alarm

Data Acquisition Product Links

Data Acquisition | Data Logger | Chart Recorder | Thermocouple | Oscilloscope | Load Cell | Pressure Sensor

© 1993-2011 Total Turnkey Solutions.