Free
Application Software: Azeotech DAQFactory Express for LabJack DAQFactory Express:
For those that have simple data acquisition and control needs and
do not want to spend a lot of money on software or do their own
programming, we offer DAQFactory Express. DAQFactory Express offers
data logging, user designable screens with trending, automation
capabilities and more. DAQFactory Express is only available with the
purchase of either the LabJack U12, UE9
and the new U3, and is included with the
purchase.
With DAQFactory Express you get:
-
Flexible Data Acquisition, read
different inputs at different intervals
- Continuous or conditional data
logging. Log to binary or ASCII files.
- Automation. Create batches or add
software process control to run your overall system. Two user definable screens you can
create on the fly using any combination of 10 different screen
components. No wiring!
- Powerful data visualization. Create
publish quality graphs.
- This and more in one easy to use,
flexible package.
CB25 Terminal Block
Compatibility: U12
Most of the connections on the LabJack U12 have built-in screw terminals, but 16 of the
digital I/O are accessed with a DB-25 connector. To ease the use of these digital ports
the CB25 provides screw terminal connections. For Labjack U12 only.
The CB25 also provides removable
short-circuit/overvoltage protection for each line.
Download
the PDF datasheet
RB16 Relay Board
Compatibility: U12
The RB16 provides a versatile method for electricians, engineers, and other qualified
individuals, to interface a LabJack U12 with high voltages/currents. The included DB25
cable connects the RB16 to a LabJack U12. The RB16 has sockets for mounting up to 16
industry standard mini I/O modules (not included). The user can also install a resistor to
bypass each socket and pass through the standard digital I/O line.
Shown with standard and miniature modules (not
included).
I/O modules are available from a variety of
manufacturers such as Grayhill, Crydom, or Kyoto, and allow the LabJack U12 to control or
monitor 120/240 VAC and/or 3-60 VDC. The following Grayhill modules are available:
70M-OAC5
(AC output),
70M-ODC5 (DC output),
70M-IAC5 (AC input),
70M-IDC5 (DC input),
Grayhill Drawings.
Download the RB16 PDF datasheet
Download the RB16 PDF schematic
EI-1022 Temperature Probe
Compatibility: U12 / UE9 /
U3
Easy to use and inexpensive temperature probe. Designed to work with a LabJack, but can
also be used with any voltage measuring device. Outputs 10 mV per degree C, and has a
range of -40 to +100 degrees C.
Download
the EI-1022 PDF datasheet
EI-1050 Digital
Temperature/Humidity Probe
Compatibility: U12 / UE9 /
U3
The EI-1050 uses two digital lines on the LabJack U12 (IO0 and IO1) to retrieve
temperature and relative humidity measurements. Featuring the Sensirion SHT11 sensor it
provides 14-bit temperature readings and 12-bit humidity readings. An enable line is
provided allowing up to 20 EI-1050 probes to be connected to a single LabJack U12.
Measurement range is -40 to 120 degrees C for temperature and 0 to 100% for humidity.
Accuracy is +/-0.5 degrees C (@ 25 deg C) and +/-3.5%. With LabJack U12 firmware version
1.10 or higher (Feb 2003 or later), it takes about 230/75 milliseconds to get a
temperature/humidity reading. With earlier firmware versions it takes about 2 seconds to
get one temperature or humidity reading.
Download
the EI-1050 PDF datasheet
EI1034 Temperature Probe
Compatibility: U12 / UE9 / U3
Easy to use, very accurate, and
waterproof temperature probe features a high-level linear output of 10
mV per degree F and a typical accuracy of +/-1 degree F.
EI-1040 Dual
Instrumentation Amplifier
Compatibility: U12 / UE9 /
U3
Dual instrumentation amplifier provides 2 high-impedance differential inputs. Operates
from a single 5 volt supply and provides a +/- 15 volt supply and a 4.096 volt reference.
Analog input range is +/- 10 volts. The gain of each channel is set to 1, 10, 100, or 1000
via digital I/O or jumper wires. Typical current requirement is about 80 mA @ 5 volts,
allowing the EI-1040 to be powered from a +5V terminal on a LabJack.
Download
the EI-1040 PDF datasheet
LabJack U12-PH OEM
Board-Only
-- OEM board-only version
of the LabJack U12. This board has pin-headers installed (component side)
instead of screw-terminals, and the LED is mounted on the component side.
Ships with the populated PCB only.
LabJack U12-NTH OEM
Board-Only
-- OEM board-only version
of the LabJack U12. This board does not have any through-hole components
installed (screw-terminals, pin-headers, LED, USB connector, and DB25
connector). Ships with the populated PCB only.
The OEM
versions do not include anything besides the board itself. Dimensional
drawings and software are available on the U12
downloads page.
LJTick-CurrentShunt:
Compatibility: U12 / UE9 /
U3
-- NOT YET AVAILABLE. The
LJTick-CurrentShunt (LJTCS) is a signal-conditioning module designed to
convert a 4-20 mA input signal into a 0.47-2.36 volt signal compatible
with the LabJack U3 or UE9.
LJTick-Divider
Compatibility: UE9 / U3
The LJTick-Divider (LJTD) is a
signal-conditioning module designed to divide 2 single-ended channels of
0-10 volt analog signals down to 0-2.5 volt signals. The 4-pin design
plugs into the standard AIN/AIN/GND/VS screw terminal block found on
newer LabJacks such as the U3 and UE9. The use of large resistors and a
precision op-amp buffer provide an input impedance of 1 MW. By adding or
replacing resistors, many other configurations are possible, such as a
level shifter that converts ±10 volts to 0-2.5 volts.
LJTick-InAmp
Compatibility: UE9 / U3
Signal-conditioning module provides two
instrumentation amplifiers ideal for low-level signals such as bridge
circuits (e.g. strain gauges) and thermocouples. The LJTIA has switches
to choose from 5 gain settings (x1, x11, x51, x201, or custom) and two
output voltage offsets. The 4-pin design plugs into the standard
AIN/AIN/GND/VS screw terminal block found on newer LabJacks such as the
U3 and UE9. (RoHS=YES)
LJTick-Proto
Compatibility: UE9 / U3
The LJTick-Proto (LJTP) consists of an
8x8 grid of holes for prototyping custom signal-conditioning ticks for
the LabJack U3 or UE9.
LJTick-RelayDriver
Compatibility: UE9 / U3
The LJTick-RelayDriver (LJTRD) allows
2 digital I/O lines on a U3 or UE9 to control a relay or other
moderate load up to 50V/200mA.
|