Total Turnkey Solutions High Speed USB Data Acquisition
HomeProductLatest News and EventsTechnical SupportContact Us

Technical & Applications Notes and more

Easy Find Index

 
DATA LOGGERS
     
 

EasyLog Data Logger Series

Low-cost, compact, battery-operated data loggers

EL-USB-1 Data Logger

EL-USB-1 Data Logger EL-USB-1-LCD Data Logger EL-USB-2+ Data Logger EL-USB-1-PRO Data Logger EL-USB-2 Data Logger EL-USB-2+ Data Logger EL-USB-2-LCD Data Logger EL-USB-2-LCD+ Data Logger EL-USB-3 Data Logger EL-USB-4 Data Logger EL-USB-5 Data Logger EL-USB-CO Data Logger EL-USB-TC Data Logger EL-USB-TC-LCD Data Logger EL-USB-RT Data Logger
-1 -1-LCD -1-RCG -1-Pro -2 -2+ -2-LCD -2-LCD+ -3 -4 -5 -CO -TC -TC-LCD -RT
 
Download the Datasheet
View Assembly
Multimedia
EasyLog Data Logger Setup
Reviewing Recorded Data
  • Programmable high and low alarm thresholds.
  • All data is recorded to built-in, non-volatile memory. EasyLog data loggers do not lose readings when the battery is discharged or replaced.
  • Automatic time and date stamping of logged data.
  • Program the logger to begin recording immediately, or at a specific date and time.
  • Bright, multi-color LEDs indicate status and alarm conditions during logging.
  • Built-in USB interface for easy setup using any PC.
  • Built-in, replaceable lithium battery (provided).
  • Intrinsic isolation for voltage and current measurements.
  • Removable cover protects the USB interface.
  • Removable clip secures the instrument during transport or deployment.
  • EasyLog application software for data logger setup, data download, and analysis.

EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line offers a specific measurement function and range.

 

Product Highlights

EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line offers a specific measurement function and range (see table).

EasyLog Products for Any Application

From temperature and humidity to carbon monoxide trending, there's an EasyLog data logger that's right for you:

Measurement

Model EL-USB
Function Range -1 -1-
LCD
-1-
RCG
-1-
Pro
-2 -2+ -2-
LCD
-2-
LCD+
-3 -4 -5 -TC -TC-
LCD
-CO -RT
Temperature -35 to +80°C
(-31 to +176°F)
                             
Temperature -40 to +125°C
(-31 to +257°F)
                           
Temperature -40 to +125°C
(-40 to +257°F)
                             
Humidity
temperature, dew point
0 to 100% RH
-35 to +80°C
(-31 to +176°F)
        * * * *              
Voltage 0 to 30 VDC                              
Process current 4 to 20 mA                              
Event, State, Count 3-28 VDC                            
Thermocouple
(no display)
-130 to +900°C (J-type)
-200 to +1300°C (K-type)
-200 to +350°C (T-type)
                             
Thermocouple
(with display)
-130 to +900°C (J-type)
-200 to +1300°C (K-type)
-200 to +400°C (T-type)
                             
Carbon monoxide 0 to 1000 ppm                              
PC Connected Temperature, Humidity, Dew Point
(Learn More)
0 to 100% RH
-20 to +70°C
(-4 to +158°F)
                           

*EL-USB-2+ provides higher accuracy measurements than the EL-USB-2 and the EL-USB-2-LCD.

Easy to Program and Deploy

Getting an EasyLogger product ready to acquire data is simple:

  1. Remove the protective USB cover.
  2. Plug the instrument into any convenient USB port.
    EL-USB-1 Data Logger in USB port
  3. Program the data logger with the provided EasyLog software:
    • Give the logger a unique name (convenient when deploying multiple units).
    • Select the required sample rate.
    • Select high and/or low alarm thresholds.
    • Select the specific date and time to begin logging.

EasyLog Data Logger Configuration Software

Now remove the data logger from the USB port, replace the USB cover, and deploy the instrument wherever you need it.

Easy to Upload and Analyze Data

Whether you want to review stored data using the supplied application or using Microsoft Excel, getting meaningful results from recorded data is fast and easy:

  1. Remove the protective USB cover.
  2. Plug the instrument back into the PC's USB port.
  3. Use EasyLog software to stop recording, access the instrument's stored data, and save it to a file that you name on the PC, all in one easy operation. The file format is Excel-compatible.
  4. Immediately EasyLog's Graph utility is enabled to display all the stored data in one compressed view.
  5. A cursor allows you to determine signal magnitude and time and date of acquisition for any value, and a magnifier utility allows you to zoom in for a closer look over any range — Easy and fast.
  6. For more custom analysis and report generation, simply import the stored data file to Microsoft Excel for virtually unlimited flexibility in how you view and interpret your results.

 

EL-DataPad

EL-DataPad for EL-USB Data LoggersThe EL-DataPad allows users of EL-USB temperature data loggers to configure their units, upload data, and view logging results on-the-spot rather than moving the logger to their PC. This allows shorter breaks in data collection for more data continuity, less travel time, and on-the-spot data review and data logger reconfiguration. Features include:

  • Archive capacity for up to 500 logger uploads
  • View uploaded data with general trend and summary reports
  • Allows full or quick set-up of compatible EL-USB data loggers
  • Touch screen interface for navigation of menus
  • 2.8 inch full color TFT display
  • Stored data can be transferred to a PC via micro USB cable
  • Rechargeable internal built-in lithium battery provides up to 8 hours of use between charges

Learn more about the EL-DataPad